Physics-based burr haptic simulation: tuning and evaluation
Proc. 12th International Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems (HAPTICS04), page 128--135 - april 2004
Télécharger la publication :
In this paper we provide a preliminary report on our work on the tuning of a temporal bone surgical simula-tor using parameter values derived from experimental mea-surements, and on the comparison between these results and the previously used domain expert assigned values. Our preliminary results indicate that the parameter values de-fined by the domain-experts are consistent with the exper-imentally derived values. Psychophysical testing indicates that the simulator is capable of rendering the basic ma-terial differences required for bone burring work and that some trained users preferentially associate a simulated tem-poral bone resin model with its real counterpart.
Images et films
Références BibTex
@InProceedings{ABGGZZPF04a,
author = {Agus, M. and Brelstaff, G. and Giachetti, A. and Gobbetti, E. and Zanetti, G. and Zorcolo, A. and Picasso, B. and Franceschini, S.},
title = {Physics-based burr haptic simulation: tuning and evaluation},
booktitle = {Proc. 12th International Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems (HAPTICS04)},
pages = {128--135},
month = {april},
year = {2004},
publisher = {IEEE Computer Society Press},
address = {Conference held in Chicago, IL, USA},
note = {idxproject: SCACMI},
url = {https://publications.crs4.it/pubdocs/2004/ABGGZZPF04a},
}