CRS4

WP3.1.1 Pool Thermal-hydraulics

Vincent Moreau
Misc - march 2017
Télécharger la publication : PresentationMYRTE201703CRS4WP311PettenWithVideo.pptx [59.3Mo]  
Progress meeting presentation illustrating the status of the CRS4 MYRRHA CFD model of the primary coolant loop. The model is operating at nominal condition with a correct free-surface level and an ACS structure model consistent with SCK.CEN input. A transient showing the system behavior under a burst of power is discussed. A variant of the ACS structure obtained at constant geometry and mesh but with changed resistance coefficient is shown to lower drastically the free-surface temperature without altering any other important parameter of the flow.

Références BibTex

@Misc{Mor17,
  author       = {Moreau, V.},
  title        = {WP3.1.1 Pool Thermal-hydraulics},
  month        = {march},
  year         = {2017},
  note         = {H2020 MYRTE Project Fourth Progress Meeting, March 9 NRG Petten, Netherlands},
  type         = {Presentation slides, H2020 MYRTE Project Fourth Progress Meeting, March 9 NRG Petten, Netherlands},
  keywords     = {MYRTE, CFD, LBE, MYRRHA},
  url          = {https://publications.crs4.it/pubdocs/2017/Mor17},
}

Autres publications dans la base

» Vincent Moreau